• On a regular interval based on a recurrence pattern: The indicator is calculated on an hourly, daily, weekly, monthly, or yearly basis, as defined in the recurrence pattern.
• Whenever a new reading is entered for one of its inputs: If the calculation uses indicator readings in calculation inputs, then whenever a new indicator reading is entered, the system recalculates the indicator. However, if there is more than one reading-based input in the calculation, the Required proximity of inputs setting can affect whether or not the recalculation occurs.
• Whenever a reading is entered for input: If the calculation uses indicator readings, the system recalculates the indicator only when a new reading is entered for the specified input. The Required proximity of inputs setting can affect whether or not the recalculation occurs.
• Manually: The indicator is recalculated when a user selects the Re-calculate Now method on the indicator.
• Full auditing – Full information is displayed on the reading’s Calculation tab
• Description and input values – The reading’s Calculation tab displays the description and input values in the text field. The table of input values is not displayed
• No auditing – The reading’s Calculation tab is not displayed