Alarm name The name of the indicator alarm. You can enter up to 50 characters to describe the alarm. See Also Severity ranking Enter a number that represents the severity of this alarm in relation to the other alarm types. Use smaller numbers for less severe alarms, and larger numbers for more severe alarms. APM multiplies the ranking of an indicator alarm by an asset's consequence priority ranking number to calculate the alarm notification ranking. The alarm notification ranking determines whether or not the alarm is shown on parent assets in the indicator monitoring panel. See Also Control the available acknowledgment methods When selected, this option enables acknowledgment methods for selection. The site’s acknowledgment policies must also support the methods you select here. See Also Create a work order Indicator alarms of this type can be acknowledged with a work order. See Also Work order from scratch is allowed Indicator alarms of this type can be acknowledged with a new work order created from scratch. See Also Create a work request, notification or request for work Indicator alarms of this type can be acknowledged with a new AWEIS work document. See Also Monitoring Indicator alarms of this type can be acknowledged by monitoring the alarm. See Also Fixed during inspection Indicator alarms of this type can be acknowledged by marking the reading as fixed during inspection. See Also Incorrect alarm Indicator alarms of this type can be acknowledged by marking the reading as an incorrect alarm. See Also Incorrect reading Indicator alarms of this type can be acknowledged by marking the reading as an incorrect reading. See Also PF Interval options Controls how the failure record’s PF interval is calculated. Options are: • Use the failure mode’s PF interval • Use the failure mode’s PF interval less the indicator’s frequency • Use the failure mode’s PF interval less the duration entered below • Do not use the failure mode’s PF interval. Use the duration entered below only See Also PF interval Duration and unit of measure used with the third and fourth options for determining the failure records PF interval. See Also Calculate the requested completion date based on the PF interval Work requests and work orders that are created from alarm acknowledgments for this state automatically have their requested completion dates calculated based on the PF interval. See Also Band or range color Select a band or range color for the chart or gauge. You can use the system/theme default or select a specific color. See Also Indicator color Select the color for the indicator on the gauge. You can choose from the system/theme default or a specific color. See Also Alarm level The level of the indicator alarm. Your choices are: • Guarded • Elevated • High • Severe See Also